PCB Trace Width Calculator
Trace width for a current (or current for a width) by IPC-2221, with resistance, voltage drop and power loss
About this Simulator
Find how wide a PCB trace must be to carry a current without overheating, or how much current an existing trace can carry. The calculator uses the IPC-2221 formula I = k·ΔT^0.44·A^0.725 for outer and inner layers and 0.5-3 oz copper, then gives the trace resistance, voltage drop and power loss for your length. Example: 1 A on a 1 oz outer layer with a 10 °C rise needs 0.30 mm (11.8 mil).
Physics & Formulas
The IPC-2221 formula
$$I = k \cdot \Delta T^{0.44} \cdot A^{0.725}$$
I is the current in amps, ΔT the temperature rise you allow above ambient in °C, and A the copper cross-section in square mils. k = 0.048 for traces on an outer layer and 0.024 for traces buried inside the board. Turn it around to get the area, then divide by the copper thickness to get the width:
$$A = \left(\frac{I}{k\,\Delta T^{0.44}}\right)^{1/0.725}, \qquad W = \frac{A}{1.378 \times \text{oz}}$$
1 oz/ft² copper is 1.378 mil (35 µm) thick, 2 oz is 2.756 mil (70 µm). 1 mil = 0.0254 mm. The formula is a curve fit to the old IPC-2221 (originally MIL-STD-275) charts, drawn for up to 35 A, widths up to 400 mil (10.2 mm), 10-100 °C rise and 0.5-3 oz copper.
Worked example: 2 A on a 1 oz outer layer, 10 °C rise
- ΔT0.44 = 100.44 = 2.754, so k·ΔT0.44 = 0.048 × 2.754 = 0.1322.
- A = (2 / 0.1322)1/0.725 = 15.131.379 = 42.4 mil².
- W = 42.4 / 1.378 = 30.8 mil = 0.78 mm.
- Resistance of 50 mm of that trace at 35 °C: R = ρL / (W·t) = 33.4 mΩ, so it drops 67 mV and burns 133 mW.
- The same 2 A on an inner layer needs 2.03 mm by IPC-2221. Allowing a 20 °C rise on the outer layer brings it down to 0.51 mm.
Trace width vs current table (IPC-2221, 10 °C rise)
| Current | 1 oz, outer layer | 1 oz, inner layer | 2 oz, outer layer |
|---|---|---|---|
| 0.5 A | 0.12 mm (5 mil) | 0.30 mm (12 mil) | 0.06 mm (2 mil) |
| 1 A | 0.30 mm (12 mil) | 0.78 mm (31 mil) | 0.15 mm (6 mil) |
| 2 A | 0.78 mm (31 mil) | 2.03 mm (80 mil) | 0.39 mm (15 mil) |
| 3 A | 1.37 mm (54 mil) | 3.56 mm (140 mil) | 0.68 mm (27 mil) |
| 5 A | 2.77 mm (109 mil) | 7.19 mm (283 mil) | 1.38 mm (54 mil) |
| 10 A | 7.19 mm (283 mil) | 18.71 mm (737 mil) | 3.60 mm (142 mil) |
Every value comes from the formula above; the calculator gives the same numbers. Widths for 10 A on 1 oz copper are past the 400 mil chart limit, so use 2 oz copper, a copper pour or a wider rise budget there.
Why "10 mil per amp" fails
Width is not proportional to current. Because I ∝ A0.725, the width grows as I1.38: going from 1 A to 2 A needs 2.6 times the width (0.30 mm to 0.78 mm), not 2 times. A fixed mil-per-amp rule is too generous at low current and dangerously thin at high current.
IPC-2221 or IPC-2152?
IPC-2152 (2009) replaced the old charts with new test data. Its main finding: inner-layer traces are not half as capable as outer ones, because the copper planes and FR-4 around them spread the heat, so IPC-2221 internal widths are conservative. Outer-layer IPC-2221 widths are close to IPC-2152 for a typical board. Use IPC-2221 for a quick, safe first size; for tight high-current layouts use IPC-2152 with your real board thickness and copper planes, then check with a thermal camera.
Sizing power traces, return paths and copper pours is a core part of Skill-Lync's PCB Design course for beginners (Altium), and the advanced PCB design course covers high-speed and multilayer boards. For a bolted enclosure or heatsink on the same board, see the bolt torque calculator; for basic V = IR checks, the Ohm's law calculator.
Formulas and table checked 16 Nov 2026 by Skill-Lync. Copper resistivity 1.724 × 10⁻⁸ Ω·m at 20 °C, temperature coefficient 0.00393 /°C.
How to Use
- Choose "Width for a current" to size a new trace, or "Current for a width" to check an existing one
- Pick outer or inner layer and the copper weight (1 oz is the default on most boards)
- Enter the current, or the width in mm, with the slider or the exact box beside it
- Set the temperature rise you can accept: 10 °C is a common conservative choice, 20-30 °C for power boards
- Enter the trace length and ambient temperature to get resistance, voltage drop and power loss
- Read the chart: the white dot is your trace on the current-vs-width curve for each copper weight
Frequently Asked Questions
What is the formula for PCB trace width?
IPC-2221 gives I = k·ΔT^0.44·A^0.725, with I in amps, ΔT the temperature rise in °C, A the cross-section in mil² and k = 0.048 (outer layer) or 0.024 (inner layer). Solve for A, then divide by copper thickness (1.378 mil per oz) to get the width in mils; multiply by 0.0254 for mm.
How wide should a PCB trace be for 1 amp?
For 1 A on 1 oz copper with a 10 °C temperature rise, IPC-2221 gives 0.30 mm (11.8 mil) on an outer layer and 0.78 mm (30.8 mil) on an inner layer. With 2 oz copper the outer-layer width halves to 0.15 mm. Many designers round up for margin.
Is there a rule of thumb for PCB trace width vs current?
Not a safe linear one. Width grows roughly as current to the power 1.38, so doubling the current needs about 2.6 times the width. On 1 oz outer copper at 10 °C rise: 0.5 A needs 0.12 mm, 1 A 0.30 mm, 2 A 0.78 mm, 5 A 2.77 mm. Use the table or the calculator instead.
Should I use IPC-2221 or IPC-2152?
IPC-2152 (2009) is the newer standard, built on fresh test data. It shows inner-layer traces run nearly as cool as outer ones, so IPC-2221 inner widths are conservative. IPC-2221 is fine for a quick, safe first size; use IPC-2152 with your real stack-up for tight high-current layouts, and verify with a thermal test.
What is the copper thickness of 1 oz PCB copper?
1 oz copper means 1 ounce of copper spread over 1 square foot, which is about 35 µm or 1.378 mil thick. 2 oz is about 70 µm (2.756 mil) and 0.5 oz about 17.5 µm. Finished outer-layer copper can be thicker after plating, which makes IPC-2221 widths slightly conservative.
Does trace width matter for signal traces?
For low-current signals the current rating is rarely the limit. Signal width is set by the controlled impedance you need (for example 50 Ω single-ended, from your stack-up) and by the fab minimum, often around 0.1-0.15 mm (4-6 mil) on a standard process. Check your fabricator's capability page before going thinner.